top of page

Hanna Hi9829
Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with optional GPS

Item# hi-4mturbphorpecdo

HI9829-EC-Probe cropped for website.jpg
  • Optional GPS provides location tracking of measurements.

  • Color coded, field replaceable sensors

  • Great for environmental, field, and laboratory testing.

The Hi9829 is available with optional GPS

The Hi9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The Hi9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.

Meter with or without GPS

gps9829b cropped.tif

Built-in GPS Receiver option provides:

  • 12 channel GPS receiver and antenna

  • Tracks location using satellites to within 30 feet

  • Latitude and longitude recorded with readings

  • Location naming for GPS coordinates

  • Distance from current location to the stored location

  • Hi929829 multiparameter water quality meter software
    supplied integrates data collected with Google™ maps ​

    • Measurement readings including GPS coordinates

    • Date and time

    • Named locations and remarks

    • Sample number

Google™ maps is a registered trademark of Google™, Inc. HANNA Instruments® has no affiliation with Google™.

HI9829-in-Case JPG.jpg

The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.

Two probes to choose from (Basic or Logging)

The Hi7609829 (basic) and Hi7629829 (logging) are multiparameter probes for use with the HI9829 portable meter.  It is an option to choose which probe will be supplied with the HI9829. By default, the HI9829 and the corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.

Hi7609829 Basic Probe

Hi7629829 Autonomously Logging Probe

HI7609829-short cropped.jpg
  • Digital probe that is less than 2 inches in diameter
     

  • 3 color-coded sensor inputs
     

  • IP68 rating for continuous immersion in water
     

  • Multistrand –multiconductor cable rated for 150 lbs (intermittent use)
     

  • Available with 4, 10, or 20-meter cable
     

  • Weighted shield protects all sensors

  • Same as basic probe but with
    logging capability
          

  • Logs data independent of HI9829 meter
     

  • Operates on 4 "AAin. batteries for up to 70 days*
     

  • Stores up to 140,000 single parameter readings or 35,000 for all parameters
     

  • Logs data from 1 second to 3 hours
     

  • Choose to be supplied with EC or EC/Turbidity sensor
     

  • Supplied with USB cable for direct connection to Window's compatible PC
     

  • *All channels logging at 10-minute intervals with no averaging

HI7629829-long cropped.jpg

*All channels logging at 10-minute intervals with no averaging

color-coded-sensors.jpg
HI9829-EC-Probe cropped 2.jpg
HI9829-in-and-out-of-case.jpg

Waterproof Protection – The water quality meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.

​

Backlit Dot Matrix LCD Display – The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.

​

Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup and logging of data. The interface is intuitive for any user's level of experience.

​

Dedicated Help Key – Contextual help is always available through a dedicated "HELPin. key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.  The help information displayed is relative to the setting/option being viewed.

​

Auto-sensor Recognition - The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.

​

Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.

​

Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.

​

Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.

​

GLP Data – HI9829 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes the date, time, buffers/standards used for calibration, and slope characteristics.

​

Data Logging – The HI9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.

​

Graphing Capability - Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.

​

PC Connectivity – Logged data can be transferred to a Windows-compatible PC with the included HI7698291 USB adapter and HI929829 software.

​

Long Battery Life - The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V "C " NiMH rechargeable batteries that provide up to 140 hours of battery life*

​

Rugged thermoformed carrying case – The HI9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.

​

* Without GPS or turbidity measurements

HI9829-Screen-GPS-Diagnostics.jpg

GPS Option

The meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.

HI9829-Screen-Graphing.jpg
HI9829-Screen-GPS-Quick_Cal.jpg

Quick Calibration

Graphing Capability

The quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.

Trend graphing with sample date and time may be viewed on the display or transferred to PC.

fast_tracker9829.jpg

Fast Tracker™—Tag Identification System

HANNA's Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.

iButton. Tags are Easy to Install

Install the optional TAGs near your sampling points for quick and easy iButton readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.

  • Specification                             Detail
     

  • sku                                                             Hi9829
     

  • pH Accuracy @ 25°C / 77°F                         ± 0.02 pH
     

  • pH Calibration                                             Automatic at 1, 2 or 3 points with automatic recognition of 5 standard                                                                                               buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer
     

  • mV Range                                                    ± 600.0 mV
     

  • mV Accuracy                                                ± 0.5 mV
     

  • ORP Range                                                   ± 2000.0 mV
     

  • ORP Accuracy (@25°C/77°F)                         ± 1.0 mV
     

  • ORP Calibration                                            Automatic at 1 custom point (relative mV)
     

  • Temperature Range                                     -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K
     

  • Temperature Resolution                               0.01 °C, 0.01 °F, 0.01 K,
     

  • Temperature Accuracy @ 25°C / 77°F          ± 0.15 °C, ± 0.27 °F, ± 0.15 K
     

  • Temperature Calibration                             Automatic at 1 custom point
     

  • EC Resolution                                              Manual: 1 µS/cm
     

  • EC Accuracy @25°C/77°F                             ± 1% of reading or ± 1 µS/cm whichever is greater
     

  • EC Calibration                                              Automatic 1 point, with 6 standard solutions (84 µS/cm, 1413 µS/cm, 5.00                                                                                         mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
     

  • TDS Resolution                                             Manual: 1 ppm (mg/L)
     

  • TDS Accuracy @ 25°C / 77°F                         ± 1% of reading or ± 1 ppm (mg/L), whichever is greater
     

  • DO Range                                                     0.0 to 500.0%
     

  • DO Resolution                                               0.1%
     

  • DO Accuracy (@25°C/77°F)                           0.0 to 300.0% saturation: ±1.5% of reading or ± 1.0% saturation whichever                                                                                        is greater, 0.00 to 30.00 ppm (mg/L): ± 1.5% of reading or ± 0.10 ppm                                                                                                (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3%                                                                                        of reading, 300.0 to 500.0% satura
     

  • DO Calibration                                              Automatic 1 or 2 points at 0, 100% or 1 custom point

Included

hi7609829-4__69177 (1).jpg

Conductivity and Turbidity Sensor

double-junction-ph-orp-sensor-hi7609829-1__10541 cropped.jpg

Double Junction pH/ORP Sensor

Galvanic DO Sensor

hi7609829-2_1507x1507_300_cmyk__02166 (1).jpg

Galvanic DO Sensor

HI9829-in-Case JPG.jpg

Durable Carrying Case

Optional

Flow Cell

Item# hi-Flowcell

​Corporate Headquarters:

531 13th Street West #307

Bradenton, FL 34211

​

Shipping and Mailing Address:

1767 Lakewood Ranch Blvd, Suite #113

Bradenton Florida 34211

​

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO)

Note: Prices on our website are in USD
Copyright Proactive Environmental Products®.
All rights Reserved.

|
|

Specifications change without notice

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures