top of page

Item# Hi-4mphecdo

Hanna Hi98494
Portable Multiparameter pH/EC/opdo® Meter with Bluetooth®

Functional and accurate, the Hanna Hi98494 is capable of testing 13 different water quality parameters using pH, EC, and optical DO sensors. Transfer data to a smart device for review or sharing with the integrated Bluetooth® connection and Hanna Lab App.


2 year manufacturer warranty

  • Waterproof ( meter rated IP67, probe rated IP68)

  • Automatic interval logging of up to 45,000 samples or log-on-demand

  • Perfect for environmental and industrial professionals.

Measurements & Logging

Measure up to 13 parameters. Don't lose important data with automatic interval logging of up to 45,000 samples or choose to log-on-demand to store measurement data for key points.



The meter operates on a built-in lithium-ion battery and will automatically switch to AA alkaline batteries for at least 200 hours of testing

GLP Data

Dual Power Source

For better traceability, calibration information is recorded along with a time and date stamp and stored with logged data.

Quick-Calibration
 

Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are also available.

Built to be Durable

Designed to withstand the knocks, drops, and spills of real life, the IP67 body ensures top performance in any environment. These meters are protected against dust and water intrusion from any direction.


A Quick Connect DIN connector makes attaching and removing the probe simple and easy. The rubber coating protects the cable and provides a water-tight seal without twisting.

Data Transfer & Charging

Quick Connect Probe

Digital Probe

The USB Type-C port provides for easy data transfer to memory stick, PC, or other device and is used to charge internal lithium-ion battery.

Digital probe with built-in temperature sensor and three ports for pH (ORP), EC and optical DO sensors. Once connected, the meter aautomatically recognize the sensors.

Multiparameter Probe and Sensors

Sensor replacement is quick and easy with field replaceable, screw type connectors and are color-coded for easy identification.

Hi7698194-0 (pH only)
Hi7698194-1 (pH/ORP)

pH/ORP Sensor

EC sensor

Hi7698194-3

Optical DO Sensor

Hi7698494-5

* The optical dissolved oxygen sensor uses a smart cap that has an RFID tag that keeps track of the age of the cap and alerts you when it should be replaced.

Connect in the Field

Sensor replacement is quick and easy with field replaceable, screw type connectors and are color-coded for easy identification.

Group your data by time or notation. Email it for storage or share it with friends or colleagues.

Good Laboratory Practices (GLP)

Sort & Share

Comprehensive GLP data can be reviewed for all parameters when the logged data is downloaded to your smart device.

Select the measurement units to be displayed on your smart device. For trend analysis, take a look at the graph of your logged data.

Measurement & Graphing

Features

HI98494 i web.tif
  • Specification                             Detail
     

  • sku                                                            Hi98494-web

  • pH Range                                                    0.00 to 14.00 pH

​​

  • pH Resolution                                             0.01 pH

  • pH Accuracy (@25°C/77°F)                         ± 0.02 pH

  • pH Calibration                                            Automatic at 1, 2 or 3 points with automatic recognition of 5                                                                                                                 standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or 1 custom buffer

  • mv Range                                                   ± 600.0 mV

  • mv Resolution                                            0.1 mV

  • mv Accuracy                                               ± 0.5 mV

  • ORP Range                                                  ± 2000.0 mV

  • ORP Resolution                                           0.1 mV

  • ORP Accuracy (@25°C/77°F)                        ± 1.0 mV

  • ORP Calibration                                           automatic at one custom point (relative mV)

                                                                           -5.00 to 55.00 °C,                           

  •  Temperature Range                                     23.00 to 131.00 °F,
                                                                        268.15 to 328.15 K

                                                                           0.01 °C,

  • Temperature Resolution                               0.01 °F,
                                                                        0.01 K

                                                                           ± 0.15 °C,

  • Temperature Accuracy                                  ± 0.27 °F,

        (@25°C/77°F)                                              ±0.15 K​​
 

  • Temperature Calibration                               automatic at one custom point

  • EC Range                                                      0 to 200 mS/cm (absolute EC up to 400 mS/cm)

​​

  • EC Resolution                                                Manual: 1 µS/cm,

                                                                            .001 mS/cm,

                                                                            00.01 mS/cm,

                                                                            0.1 mS/cm,

​                                                                            1 mS/cM Automatic: 1 µS/cm from 0 to 9999 µS/cm,
                                                                            0.01 mS/cm from 10.00 to 99.99 mS/cm,
                                                                            0.1 mS/cm from 100.0 to 400.0 mS/cM Automatic (mS/cm): 0.001                                                                                                                mS/cm   -   from 0.000 to 9.999

  • EC Accuracy (@25°C/77°F)                            ±1 % of reading or ±1 µS/cm whichever is greater

  • EC Calibration                                              automatic single point,
                                                                        with six standard solutions (84 µS/cm,
                                                                        1413 µS/cm,
                                                                        5.00 mS/cm,
                                                                        12.88 mS/cm,
                                                                        80.0 mS/cm,
                                                                        111.8 mS/cm) or custom point

  • TDS Range                                                    0 to 400000 ppm (mg/L)

  • TDS Resolution                                             Manual: 1 ppm (mg/L),
                                                                        0.001 ppt (g/L),
                                                                        0.01 ppt (g/L),
                                                                        0.1 ppt (g/L),
                                                                        1 ppt (g/L)Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L),
                                                                        0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L),
                                                                        0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L),

  • TDS Accuracy (@25°C/77°F)                         ±1 % of reading or ±1 ppm (mg/L) whichever is greater

  • TDS Calibration                                           based on conductivity or salinity calibration

  • DO Range                                                    0.0 to 500.0 %,
                                                                       0.00 to 50.00 ppm (mg/L)

  • DO Resolution                                             0.1 %,
                                                                       0.01 ppm (mg/L)

  • DO Accuracy (@25°C/77°F)                          0.0 to 300.0 %: ± 1.5 % of reading or ± 1.0 % whichever is greater,
                                                                       300.0 to 500.0 %: ± 3 % of reading0.00 to 30.00 ppm (mg/L): ± 1.5 % of                                                                                                 reading or ±0.10 ppm (mg/L)whichever is greater,
                                                                       30.00 ppm (mg/L) to 50.00 ppm (mg/L): ± 3 % of reading

  • DO Calibration                                            automatic one or two points at 0 and 100% or one custom point

  • Resistivity Range                                          0 to 999999 ©·cm,
                                                                        0 to 1000.0 k©·cm,
                                                                        0 to 1.0000 M©·cm

  • Resistivity Resolution                                  Depending on resistivity reading

  • Resistivity Accuracy                                     Based on conductivity or salinity calibration

        (@25°C/77°F) 

  • Salinity Range                                              0.00 to 70.00 PSU

  • Salinity Resolution                                       0.01 PSU

  • Salinity Accuracy (@25°C/77°F)                   ±2% of reading or ±0.01 PSU whichever is greater

  • Salinity Calibration                                      based on conductivity calibration

  • Connectivity                                                USB to PC with HI9298194 Hanna software installed

  • GLP                                                              Yes

  • Power Supply                                              1.5V AA batteries (4)

  • Power Consumption                                    approximately 360 hours of continuous use without backlight (50 hours                                                                                               with backlight)

  • Environment                                                 0 to 50°C (32 to 122°F),
                                                                         RH 100% (IP67)

​​

  • Dimensions                                                   185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in.)

​​

  • Weight                                                           400 g (14.2 oz.)

​​

  • Order Information                                         Each HI98494 is delivered in a rugged carrying case and is supplied with:                                                                                                HI7698494 Multi-sensor probe,
                                                                          HI7698194-1 pH/ORP sensor,
                                                                          HI7698194-3 EC/TDS/Resistivity/Salinity sensor,
                                                                          HI7698494-5 Optical DO sensor,
                                                                          HI764113-1 DO Smart Cap

​​

  • Warranty                                                        2 years

​​

  • Recommended Probe                                     HI7698494 multiparameter probe,
                                                                          HI7698194-1 pH sensor,
                                                                          HI7698194-1 pH/ORP sensor,
                                                                          HI7698194-3 EC sensor,
                                                                          HI7698494-5 optical DO sensor

Included

double-junction-ph-orp-sensor-hi7609829-1__10541 cropped.jpg

Double Junction pH/ORP Sensor

EC sensor

Optical DO Sensor

Galvanic DO Sensor

HI9829-in-Case JPG.jpg

Durable Carrying Case

Optional

Flow Cell

Item# hi-Flowcell

Corporate Headquarters:

531 13th Street West #307

Bradenton, FL 34211

Shipping and Mailing Address:

1767 Lakewood Ranch Blvd, Suite #113

Bradenton Florida 34211

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO)

Note: Prices on our website are in USD
Copyright Proactive Environmental Products®.
All rights Reserved.

|
|

Specifications change without notice

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2025 Proactive Environmental Products LLC®. All rights Reserved.

bottom of page