top of page

Item# hi-4mphecturbopdo

Hanna Hi98594
Portable Multiparameter pH/EC/Turbidity/opdo® Meter with Bluetooth®

Our Portable Hi98594 Multiparameter pH/EC/Turbidity/odpo® Meter with Bluetooth® (Hi98594) makes testing simple and convenient. Monitor up to 14 different water quality parameters with just one device including pH, ORP, turbidity, EC/TDS, dissolved oxygen, resistivity, salinity, seawater σ, atmospheric pressure, and temperature.
 

Be up in running in no time with this complete kit! This meter arrives in a protective, heavy-duty carrying case and is ready to use right from the get-go with all essential supplies and accessories stored in one place. Customize this meter to fit your testing requirements and choose from several cable length options.

2 year warranty

  • Handheld, portable size. Test anywhere in the field or at multiple facility checkpoints with this versatile meter. Easily take this meter with you and measure wherever you need to

  • Rugged and durable. This tough meter is waterproof and built to withstand harsh outdoor environments and conditions. Can handle the knocks and drops that may occur while testing

  • Fast and accurate. Our high-performance meter delivers precise results in the palm of your hand. Cut down on testing time and collect quick, consistent, and reliable measurements on the spot

  • Environmental Water Quality

  • Water Treatment 

  • Industrial 

  • Laboratory 

  • Education and Research

  • Beverage Manufacturing

  • Aquaculture

  • Municipalities 

Connection Options Hi98594 Multiparameter

  • This meter is equipped with Bluetooth® 5.0 wireless technology and is Hanna Lab App compatible 

  • The Hanna Lab App now features Hanna Cloud compatibility

  • Download and transfer logged data as a CSV or PDF file 

  • Easily review data and access or email log lots using a phone or tablet with Bluetooth® connection and the Hanna Lab App

  • USB Type-C port can be used to charge the meter and export data via a USB Flash Drive or direct PC connection  

  • Capable of remote firmware updates via the Hanna Lab App

Equipped with Bluetooth® 5.0 wireless technology. Gain full visibility and traceability over GLP data. Simply connect your phone or tablet via Bluetooth® and use the Hanna Lab App to transfer, review or email batches of logged data.

Achieve peace of mind with water analysis results at your fingertips

What's Included

  • Portable Multiparameter pH/EC/Turbidity/opdo® Meter with Bluetooth® (Hi98594) supplied with rugged carrying case

  • Multisensor probe (Hi7698594) (1 pc.) 

  • pH/ORP Sensor that is pre-installed on the probe (Hi7698194-1) (1 pc.) 

  • EC/Turbidity sensor that is pre-installed on the probe (Hi7698594-4) (1 pc.) 

  • Optical DO Sensor that is pre-installed on the probe (Hi7698594-5) (1 pc.)

  • DO Smart Cap with o-ring (Hi764113-1) (1 pc.)

  • Long Protective Probe Shield (Hi7698296) (1 pc.)

  • Long Calibration Beaker (Hi7698293) (1 pc.) 

  • Quick Calibration Standard Solution 230 mL (1 pc.)

  • Zero Oxygen Solutions Set 120 mL (1 pc.) 

  • 0 FNU Calibration Solution 230 mL (Hi9829-16) (1 pc.) 

  • 20 FNU Calibration Solution 230 mL (Hi9829-17) (1 pc.) 

  • 200 FNU Calibration Solution 230 mL (Hi9829-18) (1 pc.) 

  • Probe Maintenance Kit (accessories box included) (1 pc.)

  • Protective Rubber Boot fitted on the meter (Hi710036) (1 pc.) 

  • USB Cable (Hi920016) (1 pc.) 

  • 1.5V AA alkaline batteries (4 pcs.)

  • Quick Reference Guide (1 pc.)

  • Meter, Smart Cap, and Probe Quality Certificates

Reporting Capabilities

  • Logged data is graphically displayed on a backlit LCD screen 

  • Features log-on-demand and automatic logging on meter for all parameters 

  • This meter can log one data point or continuously log at selected time intervals 

  • There is an option for logged data to be stored in a named lot with the ability to add comments

  • All Good Laboratory Practice (GLP) data is stored. Calibration information is captured with time and date stamp and includes calibration values as well as other values that can impact the measurement

  • GLP feature allows for the last five calibrations to be stored automatically 

  • There are many benefits to using the Hanna Lab App to analyze logged data on a phone or tablet. Users are able to review comprehensive GLP data for all parameters, have the option to graph logged data for trend analysis, and can select the measurement units to be displayed independently of the meter settings 

Connect in the Field

Sensor replacement is quick and easy with field replaceable, screw type connectors and are color-coded for easy identification.

Group your data by time or notation. Email it for storage or share it with friends or colleagues.

Good Laboratory Practices (GLP)

Sort & Share

Comprehensive GLP data can be reviewed for all parameters when the logged data is downloaded to your smart device.

Select the measurement units to be displayed on your smart device. For trend analysis, take a look at the graph of your logged data.

Measurement & Graphing

Features

HI98494 i web.tif

Features

  • Ideal for environmental and field measurements 

  • Rugged design includes water-resistant meter and waterproof probe

  • Meter features an easy-to-read graphic backlit display with on-screen graphing capability 

  • User-friendly and easy to operate. Testing is hassle-free with this meter's intuitive keypad and straightforward navigation menus

  • Multiple cable length options are available

  • Monitors up to 14 water quality parameters (7 measured and 7 calculated) including pH, ORP, turbidity, EC/TDS, dissolved oxygen, resistivity, salinity, seawater σ, atmospheric pressure, and temperature

  • Each parameter is completely configurable

  • Achieve instantaneous conductivity and turbidity measurements

  • Meter is enclosed in an IP67-rated waterproof casing and can be immersed in water at a depth of 1 m for up to 30 minutes

  • Multisensor probe (Hi7698594) is IP68-rated for continuous submersion in water and is totally sealed against water and dust

  • This meter will automatically detect when the probe is securely connected. Meter attaches to the multisensor probe through a single waterproof quick din connector which makes fastening and removing the probe convenient

  • The multisensor probe is supplied with pre-installed pH/ORP, EC, turbidity, and optical dissolved oxygen sensors. These replaceable field sensors are automatically recognized by the meter  

  • The optical dissolved oxygen sensor uses a smart cap that has an RFID tag that stores calibration coefficients unique to each cap. The RFID keeps track of the age of the cap and alerts the user when it's time for replacement

  • Changing a sensor is fast and simple. All field sensors are constructed with a replaceable, screw type connector and are color coded for easy identification

  • pH, EC, and dissolved oxygen measurements are automatically compensated for temperature variations

  • This meter is designed with a built-in barometer for percent saturation and dissolved oxygen measurement compensation. All dissolved oxygen concentration measurements are automatically compensated for barometric pressure and salinity

  • Quick calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available for pH up to three points, conductivity at one-point, dissolved oxygen up to two points, and turbidity with three provided standards 

  • Manufactured with a dual power source battery system for extended use in the field. This meter operates on a built-in lithium-ion battery. Once the rechargeable batteries run low, the meter will automatically switch and default to the 1.5 AA alkaline batteries  

Included

double-junction-ph-orp-sensor-hi7609829-1__10541 cropped.jpg

pH/ORP Sensor

Conductivity and Turbidity Sensor

image.png

Optical DO Sensor

Sturdy Carrying Case

Optional

Flow Cell

Item# hi-Flowcell

  • Specification                             Detail
     

  • sku                                                            Hi98594-web

  • pH Range                                                    0.00 to 13.00 pH

​​

  • pH Resolution                                             0.01 pH

  • pH Accuracy (@25°C/77°F)                          0.05 pH (Accuracy is evaluated with a calibrated system at ambient temperature.)

  • pH Calibration                                            One point using HI9828-20 Quick Calibration Solution Up to three points using H 4.01,                                                                         ppH 6.86, pH 7.01, pH 9.18, pH 10.01 standard buffers  and one customer buffer

  • mv Range                                                   ± 600.0 mV

  • mv Resolution                                            0.1 mV

  • mv Accuracy                                               ±3.0 mV (Accuracy is evaluated with a calibrated system at ambient temperature.)

  • ORP Range                                                  ± 2000.0 mV

  • ORP Resolution                                           0.1 mV

  • ORP Accuracy (@25°C/77°F)                        ± 1.0 mV

  • ORP Calibration                                           automatic at one custom point (relative mV)

                                                                          -5.00 to 55.00 °C,                           

  •  Temperature Range                                    23.00 to 122.00 °F,
                                                                       268.15 to 323.15 K

                                                                           0.01 °C,

  • Temperature Resolution                               0.01 °F,
                                                                        0.01 K

                                                                           ± 0.15 °C,

  • Temperature Accuracy                                  ± 0.27 °F,

                                                                           ±0.15 K​​
 

  • Temperature Calibration                               automatic at one custom point

  • EC Range                                                       0 to 200 mS/cm; 0 to 400 mS/cm (absolute)

​​

  • EC Resolution                                                Manual: 

                                                                            1 µS/cm

                                                                            0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm

                                                                            Automatic:

                                                                            1 µS/cm from 0 to 9999 µS/cm

​                                                                            0.01 mS/cm from 10.00 to 99.99 mS/cm
                                                                            0.1 mS/cm from 100.0 to 400.0 mS/cm
                                                                        
                                                                            Automatic (mS/cm):

                                                                              .001 mS/cm from 0.000 to 9.999 mS/cm

                                                                                 0.01 mS/cm from 10.00 to 99.99 mS/cm
                                                                            0.1 mS/cm from 100.0 to 400.0 mS/cm

  • EC Accuracy (@25°C/77°F)                            ±1% of reading or ±1 µS/cm, whichever is greater (Accuracy is evaluated with a                                                                                  calibrated system at ambient temperature.)

  • EC Calibration                                              One point using HI9828-20 Quick Calibration Solution
                                                                        One point using 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm,                                                                                  111.8 mS/cm standard solutions or custom point

  • TDS Range                                                    0 to 400000 ppm (mg/L)

  • TDS Resolution                                             Manual: 

                                                                           1 ppm (mg/L)

                                                                           0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L)

                                                                           Automatic:

                                                                           1 µS/cm from 0 to 9999 µS/cm

​                                                                           0.01 mS/cm from 10.00 to 99.99 mS/cm
                                                                           0.1 mS/cm from 100.0 to 400.0 mS/cm
                                                                        
                                                                           Automatic (mS/cm):

                                                                            .001 mS/cm from 0.000 to 9.999 mS/cm

                                                                               0.01 mS/cm from 10.00 to 99.99 mS/cm
                                                                           0.1 mS/cm from 100.0 to 400.0 mS/cm

  • TDS Accuracy (@25°C/77°F)                         ±1 % of reading or ±1 ppm (mg/L) whichever is greater

  • TDS Calibration                                            based on conductivity or salinity calibration

  • DO Range                                                      00.1 % saturation;

                                                                              0.01 ppm (mg/L)

  • DO Resolution                                               0.1 %,
                                                                         0.01 ppm (mg/L)

  • DO Accuracy                                                 ±1.5 % of reading from 0.0 to 200.0 % saturation
                                                                        ±5 % of reading from 200.0 to 500.0 % saturation
                                                                        ±1.5 % of reading from 0.00 to 20.00 mg/L
                                                                        ±5 % of reading from 20.00 to 50.00 mg/L
                                                                        (Accuracy is evaluated with a calibrated system at ambient temperature.)

  • DO Calibration                                               One point, quick calibration in water-saturated air
                                                                          One or two points, at 100 % and 0 %
                                                                          One point, using a custom solution (% saturation or mg/L)

  • Barometric Pressure Range                       450.0 to 850.0 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436                                                                                psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa​​

  • Barometric Pressure Resolution               0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa

  • Barometric Pressure Accuracy                 ±3.0 mmHg within ±15 °C from calibration temperature

  • Barometric Pressure Calibration              Automatic at one custom point

  • Resistivity Range                                           0 to 999999 Ω·cm; 0 to 1000.0 kΩ·cm (depending on resistivity reading); 0 to 1.000 MΩ·cm

  • Resistivity Resolution                                  1 Ω·cm; 0.1 kΩ·cm; 0.0001 MΩ·cm

  • Resistivity Calibration                                  Based on conductivity calibration

  • Salinity Range                                                0.00 to 70.00 PSU

  • Salinity Resolution                                        0.01 PSU

  • Salinity Accuracy                                           ±2 % of reading or ±0.01 PSU, whichever is greater

  • Salinity Calibration                                        One point, using a custom solution

  • Seawater Sigma Range                                  0 to 50.0 σt, σ0,σ15

  • Seawater Sigma Resolution                         0.1 σt, σ0,σ15

  • Seawater Sigma Accuracy                             ±1.0 σt, σ0,σ15

  • Seawater Calibration                                     Based on conductivity or salinity calibration

  • Turbidity Range                                               0.0 to 99.9 FNU; 100 to 1000 FNU

  • Turbidity Resolution                                      0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU

  • Turbidity Accuracy                                            ±0.3 FNU or ±2 % of reading, whichever is greater (Accuracy is evaluated with a                                                                                   calibrated system at ambient temperature.)

  • Turbidity Calibration                                         Automatic, Up to three points using 0 FNU, 20 FNU, 200 FNU, or custom

  • DO Pressure Compensation                               Automatic; 450 to 850 mmHg

  • Temperature Compensation                              Automatic; -5 to 50 °C; 23 to 122 °F; 268.15 to 323.15 K

  • Logging Memory                                               Interval logging
                                                                             50000 records

                                                                             Log-on-demand (all parameters)
                                                                             20000 records

  • Logging Interval                                                1 second to 3 hours

  • USBC (Host) Functions                                       Mass-storage host

  • USBC (Device) Functions                                    Mass-storage device

  • Protection Rating                                              IP67

  • Environment                                                     0 to 50 °C (32 to 122 °F); RH 100 %

  • Battery Type                                                     4 x 1.5V AA alkaline batteries
                                                                            1 X internal, Li-ion rechargeable battery

  • Battery Life                                                      ≈ 126 hours
                                                                           90 hours using alkaline AA batteries
                                                                           36 hours using Li-ion battery (Estimated time given without backlight and                                                                                           Bluetooth®.)

  • Dimensions                                                     185 X 93 X 35.2 mm (7.3 X 3.6 X 1.4")

  • Weight                                                             435 g (13.3 oz) (with batteries)

Corporate Headquarters:

531 13th Street West #307

Bradenton, FL 34211

Shipping and Mailing Address:

1767 Lakewood Ranch Blvd, Suite #113

Bradenton Florida 34211

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO)

Note: Prices on our website are in USD
Copyright Proactive Environmental Products®.
All rights Reserved.

|
|

Specifications change without notice

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2025 Proactive Environmental Products LLC®. All rights Reserved.