Hanna Hi98703
ISO Turbidity Portable Meter

Item# Hanna Turbidity

HI98703-Front-Cover-Closed__36479 slim crop.jpg
  • Never miss a measurement with stored logging.

  • GLP (Good Laboratory Practice) function for calibration traceability.

  • Specially designed for water quality measurements.

The Hi98703 is a high accuracy (±2% of reading plus 0.02 NTU) Turbidity Portable Meter. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification.

The Hi98703 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.

2 year manufacturer warranty

The Hi98703 Precision Turbidity Portable Meter is specially designed for water quality measurements, providing reliable and accurate readings, especially in the low turbidity range. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.

Features at-a-glance

Multiple reading modes - Normal measurement, continuous measurement, or signal averaging measurement are reading modes available.

EPA Compliant Measurement - The Hi98703 meets and exceeds the requirements of EPA and Standard Methods for turbidity measurements. When the meter is in EPA mode all turbidity readings are rounded accordingly to meet reporting requirements.

Calibration – A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.10, 15.0, 100, and 750 NTU) standards. Calibration points can be modified if user-prepared standards are used.

AMCO AEPA-1 Primary Turbidity Standard - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.

Fast Tracker™ - For advanced field applications, the Hi98703 is equipped with Fast Tracker™ - Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® tag contains a computer chip with a unique identification code encased in stainless steel.

GLP Data – The Hi98703 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.

Data Logging – Up to 200 measurements can be stored in the internal memory and recalled at any time.

Data Transfer – For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the RS232 or USB port and the Hi92000 software.

Backlit Display – A backlit LCD display provides an easy to understand, user-friendly interface. Displayed codes guide the user step-by-step through routine operation and calibration.

Significance of Use

  • Turbidity is one of the most important parameters used to determine the quality of drinking water. Once considered as a mostly aesthetic characteristic of drinking water, significant evidence exists that controlling turbidity is a competent safeguard against pathogens. In natural water, turbidity measurements are taken to gauge general water quality and its compatibility in applications involving aquatic organisms. The monitoring and treatment or wastewater was once solely based on the control of turbidity. Currently, the measurement of turbidity at the end of the wastewater treatment process is necessary to verify that the values are within regulatory standards.

    Turbidity of water is an optical property that causes light to be scattered and absorbed, rather than transmitted. The scattering of light that passes through a liquid is primarily caused by the suspended solids present. The higher the turbidity, the greater the amount of scattered light. Even a very pure liquid will scatter light to a certain degree, as no solution will have zero turbidity.

    Drinking water treatment plants that obtain water from surface water are required by the EPA to monitor and report the turbidity. Surface water sources include lakes and rivers. The requirements of the nephelometer and reporting measurements according to EPA Method 180.1 are:

     

  • The applicable range is 0-40 nephelometric turbidity units (NTU)

  • Light source: Tungsten lamp operated at a color temperature between 2200-3000°K.

  • Distance traversed by incident light and scattered light within the sample tube: Total not to exceed 10 cm.

  • Detector: Centered at 90° to the incident light path and not to exceed ±30° from 90°. The detector, and filter system if used, shall have a spectral peak response between 400 nm and 600 nm

  • The sensitivity of the instrument should permit detection of a turbidity difference of 0.02 NTU or less in waters having turbidities less than 1 unit.

turbidity-portable-meter-open-side-hi98703__70186__11107.jpg

Report results as follows:       

 

   NTU reading                                                                             Rounded to nearest

​

   0.0 - 1.0​                                                                                    0.05

​

   1 - 10                                                                                         0.1

​

   10 - 40                                                                                       1

​

   40 - 100                                                                                      5

​

   100 - 400                                                                                   10

​

   400 - 1000                                                                                  50

​

   >1000                                                                                        100

​


The Hi98703 meets and exceeds the meter criteria specied by the EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B.

light-diagram-2.webp
turbidity-portable-meter-back-hi98703__92935__20971.jpg

Principle of Operation

The light beam that passes through the sample is scattered in all directions. The intensity and pattern of the scattered light is affected by many variables, such as wavelength of the incident light, particle size and shape, refractive index, and color. The optical system of the HI98703 includes a tungsten fi˜lament lamp, a scattered light detector (90°) and a transmitted light detector (180°).

In the ratio turbidimeter range, the microprocessor of the instrument calculates the NTU value from the signals that reach the two detectors by using an effective algorithm that corrects and compensates for interferences of color. The optical system and measuring technique also compensate for fluctuations in lamp intensity, minimizing the need for frequent calibration.

In the non-ratio turbidimeter range, the NTU value is calculated from the signal on the scattered light detector (90°). This method offers a high linearity on the low range but is more sensitive to lamp intensity fluctuations. The lower detection limit of a turbidimeter is determined by stray light that is detected by the sensors but not caused by light scattering from suspended particles. The optical system of the HI98703 is designed to have very low stray light, providing highly accurate results for low turbidity samples.

The HI98703-11 AMCO AEPA-1 standards ensure that measurements are traceable to a primary reference materials. These standards are used for calibration and performance verification of the turbidity meter.

Supplied with Certificate of Analysis

  • Lot number

  • Expiration date

  • Standard value @ 25 °C

  • Reference meter NIST traceable


Provided storage containers

  • Light tight

  • Protects from accidental breakage

reagnets-hi98703 crop.jpg
  • Specification                                  Detail 

​

  • sku                                                 Hi98703-01

​

  • NTU Range                                      0.00 to 9.99 NTU                                                                                                                                                                                    10.0 to 99.9 NTU                                                                                                                                                                                      100 to 1000 NTU

​

  • NTU Resolution                               0.01 NTU from 0.00 to 9.99 NTU                                                                                                                                                               0.1 NTU from 10.0 to 99.9 NTU                                                                                                                                                               1 NTU from 100 to 1000 NTU

​

  • NTU Accuracy                                  ±2% of reading plus 0.02 NTU

​

  • Range Selection                               Automatic

​

  • Turbidity Repeatability                    ±1% of reading or 0.02 NTU, whichever is greater

​

  • Stray Light                                      < 0.02 NTU

​

  • Turbidity Light Detector                  Silicon Photocell

​

  • Turbidity Method                           Ratio Nephelometric signal (90') scatter light ratio transmitted light                                                                                                      Adaptation of the USEPA Method 180.1 and Standard Method 2130 B

​

  • Turbidity Standards                        15, 100 and 750 NTU

​

  • Calibration                                      One, two or three point calibration

​

  • Light Source                                   Tungsten filament lamp

​

  • Lamp Life                                       Greater than 100,000 readings

​

  • Display                                           60 x 90 mm LCD with backlight

​

  • LOG Memory                                  200 records

​

  • Serial Interface                               RS232 or USB 1.1

​

  • Environment                                  0 to 50 °C (32 to 122 °F) max 95% RH non-condensing

​

  • Power Supply                                 4 x 1.5V AA alkaline batteries or AC adapter

​

  • Auto Shut-Off                                 After 15 minutes of non-use

​

  • Dimensions                                    224 x 87 x 77 mm (8.8 x 3.4 x 3.0in.)

​

  • Weight                                           512 g (18 oz.)

​

  • Warranty                                        2 years

Included

HI731331N-1200by1200__99003.jpg

22 mm Glass Cuvettes

Caps for Glass Cuvettes

caps-for-cuvettes-hi731335n__42711.jpg

Cuvette Cleaning Solution

silicone-oil-15ml-hi98703-58__30032.jpg

Silicone Oil (15 mL)

Durable Carrying Case

reagnets-hi98703 crop.jpg

AMCO-AEPA-1 primary turbidity standards

​Corporate Headquarters:

531 13th Street West #307

Bradenton, FL 34211

​

Shipping and Mailing Address:

1767 Lakewood Ranch Blvd, Suite #113

Bradenton Florida 34211

​

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO)

Note: Prices on our website are in USD
Copyright Proactive Environmental Products®.
All rights Reserved.

|
|

Specifications change without notice

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2025 Proactive Environmental Products LLC®. All rights Reserved.

bottom of page