MiniRAE 3000+

The MiniRAE 3000 PID is the most advanced handheld volatile organic compound (VOC) detector on the market. Its Photoionization Detector (PID) extended range of 0 to 15,000 ppm makes it an ideal instrument for applications from industrial hygiene, to leak and hazmat detection.

​

The RF modem allows real-time data transmissions with a base controller located up to 500 feet (or two-miles with optional RAELink2 portable modem) away from the MiniRAE 3000 detector.

​

A personal computer can be used as the base station for a Mini-RAE 3000 system. The standard ProRAE Remote software is capable of monitoring the input of up to 64 remotely-located monitors like MiniRAE 3000, or AreaRAE, etc.

minirae-3000 png.png

Benefits:   â€‹

  • Highly connectivity capability through multiple wireless module options

  • Large graphic display for easy overview of concentration

  • Integrated flashlight for better visibility in low light

  • Multi-language support with 10 languages encoded

  • Low maintenance—easy access to lamp and sensor

 Features:   

  • Humidity compensation with built-in humidity and temperature sensors

  • VOC detection range from 0 to 15,000 ppm

  • IP- 67 waterproof design

  • 3-second response time

  • Six-month data logging

  • Third-generation patented PID technology

  • Reflex PID TechnologyTM

Specifications:

SENSORS:                              Photoionization sensor with standard 10.6eV or optional 9.8eV or 11.7eV lamp 

BATTERY:                              Rechargeable external field-replaceable Lithium-Ion battery pack

                                            Alkaline battery adapter

DISPLAY GRAPHIC:                 4 lines 28 x 43 mm with LED backlight for enhanced display readability

CALIBRATION:                       Two-point or three-point calibration for zero and span. Calibration memory for 8                                                      calibration gases, alarm limits, span values, and calibration dates

DATA LOGGING:                     Standard 6 months at one-minute intervals 

SAMPLING PUMP:                  Internal, integrated flow rate at 500 cc/mn

                                             Sample from 100' (30m) horizontally and vertically

HUMIDITY:                            0% to 95% relative humidity (non-condensing)

TEMPERATURE:                      -4° to 122° F (-20° to 50° C)

MEASUREMENTS:                  10” Length x 3.0” Width x 2.5” Height (25.5 cm x 7.6 cm x 6.4 cm)

WEIGHT:                               26 oz (738 g)

Kit includes: 

  • MiniRAE 3000+ Monitor, Model PGM-7320

  • Flex-I-Probe

  • External filter (2)

  • Yellow rubber boot (as installed on monitor)

  • Alkaline battery adapter

  • Lamp cleaning kit and Tool kit

  • Lithium-ion (Li-ion) battery with universal AC/DC adapter and international plug kit

  • Charging/download cradle 

  • Operation & Maintenance manual

  • 5 Porous metal filters and O-rings

  • Organic vapor zeroing kit

  • Gas outlet port adapter and tubing

  • USB Cable 

  • Quick Start Guide

  • Hard transport kit with pre-cut foam padding

Rae Systems is a registered trademark of Honeywell International Inc.

​Corporate Headquarters:

9040 Town Center Parkway, Suite 101

Lakewood Ranch, Florida 34202

​

Shipping and Mailing Address:

1767 Lakewood Ranch Blvd, Suite #113

Bradenton Florida 34211

​

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO)

Note: Prices on our website are in USD
Copyright Proactive Environmental Products®.
All rights Reserved.

|
|

Specifications change without notice

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

Copyright 2025 Proactive Environmental Products LLC®. All rights Reserved.

bottom of page