Item# PA-10950

PROACTIVE ENVIRONMENTAL PRODUCTS®

Low Flow with Power Booster 4 Controller

Engineered specifically for Proactive Environmental Products Int'l®

12 volt Abyss 300 and the 12 volt Abyss 300 Slimline Plastic Pumps

 

The Proactive® Low Flow with Power Booster 4 Controller is engineered specifically for the 12 volt Abyss 300® and the 12 volt Abyss 300® Slimline plastic pumps. This device will allow the user to regulate low flow sampling (Fractional Flow®) as low as 40 mL/s per min. Simply connect the booster to a 12 volt deep cycle battery and connect the pump to the booster and stand back for awesome pumping power!

 

Check out all the great features of the Low Flow with Power Booster 4 Controller

  • Heavy-duty steel weatherproof case

  • Low voltage disconnect (LVD) at 10.75 volts (turns off controller or allows pump to pulsate)

  • Constant Voltage Boosting Technology (CVBT) allows the correct voltage to reach the pump motors

  • 30 AMP "safety" fuse to protect electronics and user

  • 6-month parts and labor warranty

  • 'Ramp Up' control dial

  • 3.5 foot wire lead to battery clamps and 4 foot wire leads to pump connector

  • Steel handle for comfort and control

 

The Abyss 300 is a registered trademark ®

Low Flow with Power Booster 4 Controller

Requires one of the following Plastic Pumps:

12 Volt Abyss 300®

(Lifts 300 Feet / 92 Meters DTW)

(For a 4" schedule 40 well or larger)

12 Volt Abyss 300 Slimline®

(Lifts 300 Feet / 92 Meters DTW)

(For a 4" schedule 80 well or larger)

   Pumping Depth in Feet              Gallons Per Minute  

    DTW (Depth To Water)       At 12.5 Volts At The Source

                  10                                          2.0

         

                  20                                          2.0

          

                  40                                        1.75

          

                  60                                        1.75

          

                  80                                        1.75

         

                100                                        1.50

         

                120                                        1.50

         

                140                                        1.50

        

                160                                        1.50

         

                180                                        1.25

         

                200                                        1.25

         

                220                                         1.0

         

                240                                         1.0                

                260                                         1.0

                280                                         0.5

                300                                         0.5

   Test was conducted with a 12 volt deep cycle battery

at 12.5 volts at battery terminals

 

Running your vehicle while using this pump

will dramatically increase purge volume