top of page

PROACTIVE ENVIRONMENTAL PRODUCTS®

12 Volt Poseidon® 100 Plastic Pump

(Lifts 100 Feet / 31 Meters)

 

For the Time Efficient, Budget Conscious Environmental Professional!

Streamline ~ Simplify

And above all... Enjoy Your Surface and Groundwater Projects!

 

Welcome to the Poseidon® Plastic Pump line!

 

 

 

 

 

 

 

The low amp draw, hardworking Poseidon® 100 Plastic Pump fits into 2-inch schedule 40 and 80, and larger diameter wells. Poseidon® 100 Plastic Pump is powered by a 12 volt DC power source such as your vehicle. For remote sites consider the Proactive® 60 AMP battery power pack,

or a 12 volt DC portable spill-safe AGM battery.

 

The Poseidon® 100 Plastic Pump is most popular for its price point, reliability, performance,  

ease-of-use, and the flexibility to be used in multiple applications!

 

The Poseidon® 100 Plastic Pump is compatible with various 12 volt DC autonomous pump control systems options to choose from, such as Proactive Environmental Products®:

 

Pro LD with Booster

 

Pro 100 Solar Charger #1

 

Pro Transformer #4

 

 

Applications of the Poseidon® 100 Plastic Pump include, but not limited to:

24/7 stationed applications in groundwater, surface water, vaults or the like for: Pump Tests, Long or Short Term Purge, Remediation, Liquid Transfer, Ongoing Groundwater and Surface Water Monitoring

Note: If you are looking for an affordable Hydrocarbon Recovery [LNAPL/DNAPL] pump please see

the SS Mini Monsoon® XL Series or Abyss® Series pump lines

Item# PPOS-1000

 Poseidon® 100 Plastic Pump 

 

The most versatile and simple-to-use surface and groundwater 12 volt DC pump on the market!

 

Explore your options!®

Find out why tens of thousands of Poseidon® 100 Pumps

are deployed at ongoing monitoring and groundwater remediation sites globally!

Benefits:  

  • Designed for the field professional

  • The most economical and simple solution for a wide range of surface and groundwater applications

  • Lightweight

  • Simple to clean and decontaminate

  • Simple and easy to use

  • Most reliable and lowest maintenance pump on the market for pump tests, remediation, monitoring, and liquid transfer

  • User intuitive

  • Improves time management and saves money by eliminating archaic, bulky, and expensive equipment

  • Reliable, rugged, and economical engineering provides healthy return on investment

  • Eliminates rental fees and rush shipment costs

  • Provides Peace of Mind when coupled with Proactive® autonomous pump control systems for woman/man less operation

  • Proven to cut-out a vast amount of health and safety pages

  • Look like a PRO when your clients see how much money you save them by incorporating Proactive® Poseidon®100 Plastic Pumps at your site into your field projects

Features:    

  • Requires the low-cost PRO Booster #1

  • Designed for 2” schedule 40 and 80 and larger diameter wells

  • Submersible, single stage centrifugal style pump

  • Consistent flow rate at 12.5 DC volts output to the pump

  • Hardworking pump with computer engineered bottom debris filter screen that allows operation under harsh conditions with higher turbidity

  • Field ready right from the box

  • Auto-Priming so in the event of a power outage the pump restart is at same pump setting

  • Sleek dome shape construction minimizes well hang-ups

  • Comes with 110 feet of wire [Do not cut wire down from manufacture setting]

  • Poseidon® 100 Plastic Pump motor modules provide 400+ hour life. True life expectancy of the motor module is around 1,000+ hours and varies upon application and conditions in the well

  • Eliminate downtime with the incorporated Proactive Environmental Products® Patented (#9450467) 1-minute quick change motor module technology

  • Required tubing size: 3/8”id x ½” od

  • PFO/PFA free

  • Warranty: Manufacturer 60 days on parts and labor

Poseidon® 100 Plastic Pump ships individually boxed and labeled providing pump model and pump serial number. Each pump is delivered field-ready and includes:

  • Pump complete with 110 feet of 10 gauge wire installed

  • Stainless Steel eye hook mounted on top of pump head for suggested,

             but optional suspension cable 

  • One installed field-ready motor module (patent #9450467)

  • One Proactive® dual purpose wrench

Specifications:
 
The Poseidon® 100 Plastic Pump consists of 4 components: The 4 Pin Bayonet Motor Module Connector, Replaceable Motor Module, Outside PVC Housing with PVC Bottom Inlet Filter Screen (Assembled as One Unit), and the Pump Wire     
 
WATT CONSUMPTION (MAX):                     255 WATTS (MAX)
DC VOLT RECOMMENDATION:                    12-15 DC (direct current) At Source
AMP CONSUMPTION (MAX):                      17 AMPS
MEASUREMENTS:                                      LENGTH 7.5" / DIAMETER: 1.82"
REQUIRED TUBING:                                   3/8" ID X 1/2" OD TUBING
SUPPLIED WITH:                                        110 FEET OF HEAVY DUTY 10 GAUGE WIRE WITH ALLIGATOR CLAMPS
PUMP CONSTRUCTION:                              PVC, POLYPROPYLENE, AND STAINLESS STEEL
 
This pump is to be used as a dedicated pump only, which means dedicated to the well or dedicated to the water 24 hours a day! Not to be used as a portable pump
​
DO NOT cut the Poseidon® 100 Pump wire down from manufacturer setting at 110 feet length to avoid motor  module damage
 
Important Notes and Friendly Reminders:
The Poseidon® 100 Pump cannot be used as a pressure pump under any circumstance. The Poseidon® 100 Pump is engineered to discharge liquid into a holding tank, not to be used in a pressurised tank application.
​
Do not restrict the Poseidon® 100 Plastic Pump using valves or any other flow restriction mechanical devises!       

This Pump Is Manufactured With PFAS-Free Parts

 Pumping Depth in Feet              Gallons Per Minute     

  DTW (Depth To Water)        At 13.8 Volts At The Source

 

               10                                          2.50

​

               20                                          2.25

​

               30                                          2.00

 

               40                                           1.75

 

               60                                          1.50

 

               70                                          1.25

 

               80                                          1.00

 

               90                                          0.75

 

             100                                          0.25

 

​

Test was conducted with a Power Source at 13.8 volts

​Corporate Headquarters:

531 13th Street West #307

Bradenton, FL 34205

​

Shipping and Mailing Address:

1767 Lakewood Ranch Blvd, Suite #113

Bradenton Florida 34211

​

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO)

Note: Prices on our website are in USD
Copyright Proactive Environmental Products®.
All rights Reserved.

|
|

Specifications change without notice

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

Copyright 2025 Proactive Environmental Products LLC®. All rights Reserved.

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures

bottom of page