Item# P-10330

PROACTIVE ENVIRONMENTAL PRODUCTS®

12 Volt Tornado® Plastic Pump

(Lifts 100 Feet / 31 Meters DTW)

The Engineered Plastic 12-volt submersible centrifugal Tornado® pump is capable of pumping up to 100 feet from ground level (DTW)* by simply connecting the Tornado® to a 12-volt deep cycle battery. Its reliable design is perfect for continuous sampling and purging of groundwater wells and Low Flow Sampling (Fractional Flow®).

 

The 12 Volt Tornado® is ideal for low flow sampling (Fractional Flow®) in conjunction with Proactive Environmental Products Low Flow Sampling Controller. Low flow sample all the way down to 40 mL/s per minute. To achieve even a lower flow.... simply add the Low Flow Sampling Control Valve in conjunction with the Low Flow Sampling controller to achieve flow rates of 10 mL/s per minute or less!

 

Simplify and Expedite Your Next Sampling Event!

  • Tornado® can operate under harsh conditions with higher turbidity.

 

  • Tornado® can run continuously in water without the need for a cool down!

 

  • Tornado® has a 400 hour motor life!

 

  • Tornado® has a sleek outside that minimizes well hang-ups.

 

  • The Tornado® is a very reliable and economical pump that provides a great bang for your buck!

 

This pump is not engineered to be dedicated in liquid 24 hours a day.

 

*Depth to water

Specifications:

POWER CONSUMPTION:                       210 WATTS (MAX)

VOLT RECOMMENDATION:                   12-15 DC (direct current) At Source

MAXIMUM AMP OUTPUT:                    14 AMPS

MEASUREMENTS:                                 LENGTH 27" / DIAMETER: 1.82"

REQUIRED TUBING:                              3/8" or 1/2" ID TUBING

SUPPLIED WITH:                                  110 FEET OF HEAVY DUTY 10 GAUGE WIRE, QUICK 

                                                           DISCONNECT PLUG & BATTERY CLAMPS   

PUMP CONSTRUCTION:                          ABS

IMPELLER CONSTRUCTION:                    POLY ACETAL (POM)

MOTOR SHAFT CONSTRUCTION:             STAINLESS STEEL 

WIRE CONSTRUCTION:                           PVC

SEAL CONSTRUCTION:                            NITRILE 

  Pumping Depth in Feet                Gallons Per Minute    

  DTW (Depth To Water)          At 12.5 Volts At The Source

                  3                                              3.75

                10                                             3.50

                20                                              3.00

                30                                             2.75

                40                                             2.50

                50                                              2.00

                60                                             1.50

                70                                             1.00

                80                                             0.50

                90                                             0.40

              100                                              0.25

Test was conducted with a 12 volt deep cycle battery

at 12.5 volts at battery terminals

Running your vehicle while using this pump

will dramatically increase purge volume

OPTIONAL:

12 Volt Crusader®

12 volt Crusader 50 Amp Gas Powered Generator

ACCESSORIES:

Our Location: 1767 Lakewood Ranch Blvd, Suite #113 Bradenton Florida 34211

Phone: 1.941.243.3930

Call Us Toll Free At:  (1.877.99.HYDRO) 

Note: Prices on our website are in USD

State Groundwater Sampling Procedures:

  • Alabama Groundwater Monitoring Well Sampling Procedures

  • Alaska Groundwater Monitoring Well Sampling Procedures

  • Arizona Groundwater Monitoring Well Sampling Procedures

  • Arkansas Groundwater Monitoring Well Sampling Procedures

  • California Groundwater Monitoring Well Sampling Procedures

  • Colorado Groundwater Monitoring Well Sampling Procedures

  • Connecticut Groundwater Monitoring Well Sampling Procedures

  • Delaware Groundwater Monitoring Well Sampling Procedures

  • Florida Groundwater Monitoring Well Sampling Procedures

  • Georgia Groundwater Monitoring Well Sampling Procedures

  • Hawaii Groundwater Monitoring Well Sampling Procedures

  • Idaho Groundwater Monitoring Well Sampling Procedures

  • Illinois Groundwater Monitoring Well Sampling Procedures

  • Indiana Groundwater Monitoring Well Sampling Procedures

  • Iowa Groundwater Monitoring Well Sampling Procedures

  • Kansas Groundwater Monitoring Well Sampling Procedures

  • Kentucky Groundwater Monitoring Well Sampling Procedures

  • Louisiana Groundwater Monitoring Well Sampling Procedures

  • Maine Groundwater Monitoring Well Sampling Procedures

  • Maryland Groundwater Monitoring Well Sampling Procedures

  • Massachusetts Groundwater Monitoring Well Sampling Procedures

  • Michigan Groundwater Monitoring Well Sampling Procedures

  • Minnesota Groundwater Monitoring Well Sampling Procedures

  • Mississippi Groundwater Monitoring Well Sampling Procedures

  • Missouri Groundwater Monitoring Well Sampling Procedures

  • Montana Groundwater Monitoring Well Sampling Procedures

  • Nebraska Groundwater Monitoring Well Sampling Procedures

  • Nevada Groundwater Monitoring Well Sampling Procedures

  • New Hampshire Groundwater Monitoring Well Sampling Procedures

  • New Jersey Groundwater Monitoring Well Sampling Procedures

  • New Mexico Groundwater Monitoring Well Sampling Procedures

  • New York Groundwater Monitoring Well Sampling Procedures

  • North Carolina Groundwater Monitoring Well Sampling Procedures

  • North Dakota Groundwater Monitoring Well Sampling Procedures

  • Ohio Groundwater Monitoring Well Sampling Procedures

  • Oklahoma Groundwater Monitoring Well Sampling Procedures

  • Oregon Groundwater Monitoring Well Sampling Procedures

  • Pennsylvania Groundwater Monitoring Well Sampling Procedures

  • Rhode Island Groundwater Monitoring Well Sampling Procedures

  • South Carolina Groundwater Monitoring Well Sampling Procedures

  • South Dakota Groundwater Monitoring Well Sampling Procedures

  • Tennessee Groundwater Monitoring Well Sampling Procedures

  • Texas Groundwater Monitoring Well Sampling Procedures

  • Utah Groundwater Monitoring Well Sampling Procedures

  • Vermont Groundwater Monitoring Well Sampling Procedures

  • Virginia Groundwater Monitoring Well Sampling Procedures

  • Washington Groundwater Monitoring Well Sampling Procedures

  • West Virginia Groundwater Monitoring Well Sampling Procedures

  • Wisconsin Groundwater Monitoring Well Sampling Procedures

  • Wyoming Groundwater Monitoring Well Sampling Procedures